DRIVE
• Lowfrictionscrewdrive(linearactuator)ratedfor-5ºFto+160ºF(-21ºCto+71ºC).Useofheaterbandsonarmand
control box will enhance performance in extreme cold temperatures.
• Poweredbya12Vmotorwithintegralcasehardenedsteelgearreducer.Motorspeedreducedto300rpm.
• Maximumopeningarcof110º.Approximateopeningtime(90º):18-22seconds,dependingonweightofgate.
POWER
• Thesystemispoweredbya12Vdc,7.0Ah,sealed,rechargeableacidbattery.
• Batterychargeismaintainedbya120Vac,18Vacoutputtransformerrectiedto14.5VdcthroughtheGTOcontrol
board. Blade-style control board fuse is rated for 25 A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated
fuses; doing so will void your warranty and may damage your control board.
• Foroptionalsolarchargingseepage2.
CONTROL
• GTOmicroprocessor-basedcontrolboardissetforpull-to-opengateinstallations.DIPswitchescanbeadjustedto
accommodate an optional kit for push-to-open gates (see Accessory Catalog).
• Controlboardhastemperaturecompensatedcircuits.
• Acircuitonthecontrolboardregulatescharging.“Sleepdraw”is25mA;“activedraw”is5to9A.
• Auto-memorizationofdigitaltransmittercode.
• GTOremote-mountedRFreceivertunedto318MHz.
• Operatorlengthwithpush-pulltubefullyretractedis46
1
/
4
”, mounting point to mounting point, arm stroke 22” max.
• Minimumgatelengthis6ft.
• Adjustableauto-close(3to120seconds),andstallforcepotentiometers.
• Powerterminalblockaccommodatesatransformerorsolarpanels(notboth).
• DIPswitchessimplifysetupofgateoperator.
• AccessoryterminalblockfullycompatiblewithGTOpushbuttoncontrols,digitalkeypads,loopsdetectors,etc.
• Controlboardallowsconnectionofsafetyedgesensorsandphotoelectricsensors.
• Audioentrapmentalarmsoundsifunitencountersanobstructiontwicewhileopeningorclosing.
OPERATIONAL CAPACITY
• TheGateCapacityChartshowsapproximatecycles,perday,youcanexpectfromtheGTO/ACCESS4000XLAutomatic
Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and
condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the specications listed
on page 2 or call (800) 543-1236 or (850) 575-4144 for more information.
* An operation cycle is one full opening and closing of the gate.
These specications are subject to change without notice.
Gate Weight
Gate Length
GTO/ACCESS SYSTEMS 4000XL Gate Capacity Chart
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery
16 ft.
14 ft.
12 ft.
6 – 10 ft.
160
170
180
190
50 lb.
150
160
170
180
100 lb.
140
150
160
170
150 lb.
130
140
150
160
200 lb.
120
130
140
150
300 lb.
110
120
130
140
400 lb.
100
110
120
130
500 lb.
90
100
110
120
650 lb.