GTO 4000XL Instruction Manual © 091610 15
RED wire to POSITIVE (+) terminal
BLACK wire to NEGATIVE (–) terminal
RED
BLACK
Step 2
IMPORTANT: Connect the BLACK battery wire to the NEGATIVE
(–) battery terminal. Connect the RED battery wire to the
POSITIVE(+)terminal.Reverse connection of wires will
damage the control board.
Step 3
Plug the transformer into the electrical outlet. (Use of a surge
protector with the transformer is strongly recommended.)
IMPORTANT: This is a class II indoor transformer; if using
transformer outdoors be sure to enclose it in a weatherproof
case.
Program Control Board
Set the Closed Position Limit (for Pull-To-Open Applications)
NOTE: For heavier gates you may need to increase the stall force (see pg 16). If the gate still does not open
or close to the limits you have set, check to ensure that the gate installation was performed correctly
according to the guidelines set forth on page 6. If the transmitter does not activate the gate operator you
may have to reset the transmitter code (see pg 17). If you have a Push-To-Open Installation, see page 22.
Step 1:
TURN CONTROL BOX ON. Your 4000XL has two Limit Settings:
OPEN Limit setting: (Gate in the OPEN POSITION/arm fully retracted). The OPEN limit can only be
adjusted by moving the gate bracket.
CLOSED Limit setting: (Gate in the CLOSED POSITION) To achieve optimum closed position, you are
required to complete the following:
Step 2
Conrm that the power switch is in the ON position and the gate is in the OPEN POSITION (arm fully
retracted).
Step 3
Activate your operator by pressing the transmitter button. Your gate should now be moving from the
fully open position toward the closed position. Prepare to STOP the gate by pressing the entry transmitter
button again when the gate reaches the desired closed position. This step may be repeated until desired
closed position is achieved.